BRK electronic FE10GR User Manual

Browse online or download User Manual for Unknown BRK electronic FE10GR. BRK electronic FE10GR User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
User’s Manual
D
ry Chemical
F
ire Extinguisher
Models FE5GR,
F
E10GR, FE1A10GR
IMPORTANT! Please read carefully and save.
This user’s manual contains important information about your fire
e
xtinguisher’s operation. If you are installing this fire extinguisher for
use b
y others, you must leave this manual—or a copy of it—with the
end user.
Read e
xtinguisher label and the entire user’s manual carefully before
installing or using the unit. Make sure everyone in your household is
com
pletely familiar with the operation of the extinguisher, and review
the instructions regularly. In an emergency, you will not have time to
read instructions.
IMPORTANT INFORMATION ABOUT
FIRE EXTINGUISHERS
NOTE: Be sure the extinguisher is rated to fight the type of fire most
likely to occur in the area you choose to install it. Since household fires
commonly start in the kitchen, you should always install an extinguisher
in the kitchen. For added security, you should also install additional
extinguishers in utility areas, and other living areas in your household.
FE5GR is rated Class 5-B:C.
FE10GR
is rated Class 10-B:C.
FE1A10GR
is rated Class 1-A:10-B:C.
READ BEFORE INSTALLING OR USING
T
HI
S F
IRE E
XT
INGUISHER!
Fire extinguishers are classified by fire type. The A, B and C
rating system defines the kinds of burning materials each fire
extinguisher is designed to fight. The numbers in front of the
A, B, or C indicate the rating for size of the fire the unit can
extinguish. Using the wrong type of fire extinguisher can do
more harm than good. Make sure you understand which fire
extinguisher to use on each class of fire!
Class A rating:
The agent/powder is suitable for
fighting small fires involving wood, paper, cloth,
rubber, and some plastics.
Class B rating: The agent/powder is suitable for
fig
hting small fires involving grease, oil, gasoline,
kerosene, and other flammable liquids.
Class C rating: The agent/powder is suitable for
fighting small fires in "live" electrical equipment.
WHE
RE TO INSTALL THIS EXTINGUISHER
A
Fire Extinguisher Should Be Mounted:
In the vicinity of (but not on or in) a potential source of heat
and/or fi
re, like an oven or stove.
Where it is easy to reach, near an exit or an escape route
from the room.
In a location that is convenient, in plain sight, and 3-1/2 to 5
f
eet (1 to 1.5 meters) above the floor.
Store the extinguisher high enough to keep it out of the reach
of small children.
On a clean, dry surface where the temperature does not go
ab
ove 120° F (49° C) or below –40° F (–40° C).
HOW TO INSTALL THIS EXTINGUISHER
INSTALL THE MOUNTING
BRACKET ON A WALL
1
. The extinguisher has a bracket for
w
all mounting.
2. Install the mounting bracket on a
wooden stud or other solid surface
t
hat will support the weight of the
e
xtinguisher using the screws or
bo
lts you purchased.
NOTE: Since wall surface types
vary, mounting screws are not
included.
Purchase screws or
bolts specifically designed for
the surface on which you will
mount the fire extinguisher. The
fire extinguisher label lists its
maximum weight. Mounting screw
head type should be #8 pan on
round head screws with #8 flat
washers.
3. After installing the mounting
bracket, replace the extinguisher
on the bracket with the label facing
outward, so the label can be easily
read. Wrap the bracket strap around
the cylinder and snap the buckle
closed.
INSTALLING THE MOUNTING BRACKET IN A
MARINE CRAFT
According to the NFPA Standard 302 (Fire protection Standard for
Pleasure and Commercial Motor Craft):
On marine craft, portable fire extinguishers shall be located to be
readily accessible. Extinguishers shall be secured with a marine
bracket to permit immediate release.
• On marine craft, extinguisher agent cylinders shall be mounted a
minimum of 2 inches (5 cm) above moist or wet surfaces to reduce
t
he d
a
nger of corrosion.
CHECKING AND INSPECTING THE
FIRE EXTINGUISHER
1. Inspect the extinguisher once a week. Remove the extinguisher
from the mounting bracket and inspect the gauge. If the yellow
po
i
n
t
e
r is i
n t
he GREEN area, the extinguisher is properly pressur-
ized and ready to use.
If the pointer drops into the RED area,
the extinguisher has lost some pressure and should be
repl
a
ced
.
2. Check for signs of damage or misuse. Make sure you can still
r
ead all the text on the label. Carefully examine the surface of
the extinguisher for corrosion. You can help prevent corrosion
b
y clea
ning the extinguisher if it gets wet or dirty. If you notice
corrosion during the warranty period, return the unit to First Alert
®
(see "Limited Warranty" at the end of this manual).
3
.
M
a
k
e sur
e t
he t
amper indicator ("safety seal") is still intact and the
nozzle is clean and unobstructed.
4
.
W
he
n y
ou fi
nish inspecting the extinguisher, always put it back
securely into the mounting bracket.
For more information about fire extinguishers, consult the NFPA
S
t
a
ndard #10, "Portable Fire Extinguishers," available from the National
Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02169,
U
SA.
Do not mount the extinguisher on drywall or plaster without
adeq
uate support. Use strong screws or bolts to mount the
bracket securely into solid wood or metal that can support
it
, like a wooden partition stud. Secure mounting is needed
s
o you can remove the extinguisher quickly and easily in an
emergency. Also, if the extinguisher is not held securely, it
could dr
op to the floor and injure people or damage the
e
xtinguisher.
DO NOT BREAK THE SAFETY SEAL! This seal prevents
a
ccidental discharge of the fire extinguisher. Break the seal
only in an emergency before using the fire extinguisher.
HO
W TO OPERATE YOUR FIRE
EXTINGUISHER IN A FIRE EMERGENCY
TO FIGHT THE FIRE
1. Remove the extinguisher from the mounting bracket.
2. Hold the unit firmly with the nozzle facing away from you. Pull out
the pin to break the “Safety Seal”. You won’t be able to squeeze
the lever until the safety seal is removed.
3. Stand back 6 feet (2 meters) from the fire and make sure the fire is
not between you and your exit.
4. Hold the extinguisher upright and aim the nozzle at the base
of the fire.
5. Squeeze and hold the lever to discharge the powder.
6.
Sweep the spray at the base of the burning material, using quick
side-to-side motions. (If the spray scatters the fire, move back.)
7. Move slowly towards the fire as the extinguisher spray pushes the
fir
e b
ack. Maintain a 6-foot (2 meter) distance between you and
t
he f
r
ont of the fire at all times.
8. Completely discharge the contents of the extinguisher and make
sur
e t
he fir
e is com
p
le
tely out. Flashbacks are common with fires.
9. For kitchen fires on a kitchen stove, turn off the stove immediately
if possible, otherwise as soon as it is safe.
10. If you suspect a fire had an electrical origin, shut off the electrical
power, if possible, without eliminating your escape route. Do not
touch electrical wires or appliances.
11. After you have completely discharged your extinguisher, leave the
building and close all the doors behind you.
AFTER THE FIRE IS EXTINGUISHED
Do not turn the electrical power back on or plug in any appliances
un
ti
l the area has been cleaned up comple
tely
.
It is very important
to remove the powder from electrical equipment after a fire. If the
powder gets wet, it can conduct electricity. (Using a dry chemical
e
xtinguisher on wet electrical equipment may be hazardous for this
reason.) This may worsen an electrical leakage problem, impair the
eq
ui
pment’s insulation, or create an electrical shock hazard.
If the fire was on a kitchen stove:
Make sure the oven and all burners are turned off.
Clean up the powder completely before using the stove or oven.
Se
e
H
o
w t
o Clean After Using a Fire Extinguisher”. Ventilate the
area thoroughly.
If y
ou thi
n
k the fi
re had an electrical origin:
Sh
ut o
f
f t
he electrical power, if possible--do not touch any
electrical wires or appliances.
Leave the building and close all doors behind you. Call the Fire
Department and have them inspect the premises. As soon as they
sa
y it’s safe to return, ventilate the area thoroughly.
Have a licensed electrician inspect your electrical system. Do not
turn the power back on or plug in any electrical equipment until
t
he i
nspe
ction has been completed.
Make sure your extinguisher may be safely and effectively
used on the small fire you want to fight. Always use extreme
cauti
on when fighting any fire. Fight a fire only where there is
a clear escape p
ath to allow you to get out safely if the fire
gets worse.
Avoid breathing smoke and heated fumes; stay low if
necessary. Burning materials will release toxic fumes.
I
nhaling these fumes may cause injury or death.
Always stand back far enough away from the fire—near an
exit—and make sure nothing is between you and your
escape route. If you get too close to a fire, you risk getting
burned or hit b
y splattering material like grease. If the fire is
too hot or smoky for you to get within 6 feet (2 meters), DO
NOT try to fight the fire yourself. Evacuate immediately and
ca
ll the Fire Department.
For fires on a kitchen stove, turn oven or burners off
i
mmediately if possible. If you can’t reach the oven or burner
controls safely, extinguish the fire first, then turn them off.
Fight the fire from an upwind direction with your back to any
strong air current. Trying to fight a fire with currents blowing
t
owards you can result in serious injury.
HO
W TO CLEAN AFTER USING A FIRE
EXTINGUISHER
N
OTE:
T
he powder spray from the extinguisher may spread over a
w
ide area, and may soil upholstery, carpets and walls.
Sweep/vacuum up as much of the powder as possible. Then use
a d
amp cloth to wipe off the remaining agent.
If you have any questions about cleaning appliances that the
agent has come into contact with, please contact the appliance
ma
nufacturer.
IF YOUR EXTINGUISHER NEEDS SERVICE
T
his fire extinguisher is rechargeable by a certified fire equipment
dealer, regardless of how much of the content was used.
O
nce a year, a certified fire equipment dealer, in accordance with the
se
rvice manual identified on the fire extinguisher label, should service
the fire extinguisher. Please refer to your local telephone directory for a
ce
rtified dealer.
D
o not try to service or repair this fire extinguisher under any
ci
rcumstances. Do not try to remove the nozzle or valve assembly.
This is a pressurized device that can cause serious injury if
tampered w
ith.
I
f there is a problem and it is still under warranty, please see “How to
Obtain Warranty Service” in the Limited Warranty.
DISPOSING OF A USED EXTINGUISHER
If you choose not to have a used extinguisher refilled or a non-working
u
nit repaired, take it outdoors, turn it upside down, and discharge it
completely. Dispose of the empty unit properly, and replace it with a
new fire extinguisher.
Never puncture, burn or expose this fire extinguisher to tempera-
tures o
ver 150° F (66° C) even if it is fully discharged. The contents
are under pressure and it could explode.
LIMITED WARRANTY
BRK Brands, Inc. ("BRK") the maker of First Alert
®
brand products,
w
arrants that for a period of ten years from the date of purchase, this
product will be free from defects in material and workmanship.
BRK, at its option, will repair or replace this product or any component
of the product found to be defective during the warranty period.
Replace
ment will be made with a new or remanufactured product or
component. If the product is no longer available, replacement may be
made with a simi
lar product of equal or greater value. This is your
exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage result-
ing from any of the following: negligent use or misuse of the product,
use on improper voltage or current, use contrary to the operating
instructions, disassembly, repair or alteration by anyone other than
BRK or an authorized service center. Further, the warranty does not
cover acts of God, such as fire, flood, hurricanes and tornadoes.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except
to the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty. Some states, provinces, or
jurisdictions do not allow the exclusion or limitation of incidental or
conse
q
ue
n
t
ia
l d
a
mages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have
o
t
he
r rights that vary from state to state, or province to province.
H
o
w t
o Obtain Warranty Service:
S
er
vice:
I
f se
rvice is required, do not return the product to your
retailer. In order to obtain warranty service, contact the Consumer
Affairs Division at 1-800-323-9005, 7:30 AM to 5:00 PM, Central
Standard Time, Monday through Friday. To assist in serving you, please
have the model number and date of purchase available when calling.
Address: 25 Spur Drive, El Paso, TX 79906
Marine Type, U.S.C.G. Type B:C, Size I
U.S.C.G. Approval Number 162.028/EX3622
Valid only with Bracket Number P87-0340
or Bracket Number B70-0161 and Strap Number S70-0007.
Bracket included.
M0
8-0
137-004
M 03/0
7
First Alert
®
is a registered trademark of the First Alert Trust.
1 2 3 4
© 2
007 BRK Brands, Inc., a Subsidiary of Jarden Corporation
3901 Liberty Street Road, Aurora, IL 60504-8122
All rights reserved.
Consumer Affairs: (800) 323-9005 • www.firstalert.com
T
hank you for choosing First Alert
®
f
or your fire extinguisher needs.
Y
ou have purchased a high quality fire extinguisher designed to
protect you and your family in case of a fire danger.
M0
8-0137-004
M 03/0
7
Remove Extinguisher
from Bracket
Break the
Safety Seal
S
queeze and Hold
Lever To Discharge
Powder. Sweep
S
ide to Side.
This extinguisher is designed for use against small fires
tha
t ha
ve just started and are small enough to fight safely.
It is not designed to fight large fires that are burning out of
control. If the fire is too hot or smoky for you to get within
6 feet (2 meters) of it, do not try to fight it yourself. Warn
e
v
er
y
one, evacuate the premises, and have someone call the
F
ire Department from outside the building. Trying to fight a
large fire yourself can result in injury or death.
D
o n
o
t puncture or burn any fire extinguisher. The contents
are under pressure
, and the extinguisher could explode.
Never locate this extinguisher close to an engine, stove or
o
ther s
our
ce o
f heat. It is pressurized and could rupture or
e
xplode if exposed to temperatures over 150° F (66° C).
T
his extinguisher contains a dry powder extinguishing agent.
The agent/powder is nontoxic, but can irritate skin. When using
this unit
,
a
void breathing the powder. Always ventilate the area
af
ter us
e
.
DO NOT CHECK THE PRESSURE OR TEST THE FIRE
EXTINGUISHER BY SQUEEZING THE LEVER, EVEN BRIEFLY.
ONCE USED, IT WILL GRADUALLY LOSE PRESSURE AND
WILL NOT BE FULLY CHARGED FOR USE IN AN EMERGENCY.
When the pointer drops into the red area, the extinguisher
ma
y s
ti
l
l be pressuriz
ed
,
but must be recharged.
Sh
own
w
ith plastic
bracket
Sh
own
w
ith metal
bracket
OR
OR
Page view 0
1

Summary of Contents

Page 1 - User’s Manual

User’s ManualDry Chemical Fire ExtinguisherModels FE5GR,FE10GR, FE1A10GRIMPORTANT! Please read carefully and save.This user’s manual contains importan

Comments to this Manuals

No comments